WASTEWATER ANALYSIS WHITE PAPERS & CASE STUDIES

Rapid Microbial Assessment Following A Case Of Legionellosis
Rapid Microbial Assessment Following A Case Of Legionellosis

A case of legionellosis an illness acquired from Legionella bacteria, which can grow in cooling water and potable water systems was diagnosed at a medical retirement home.

  • Are You Experiencing Deviation Alarms In Your High Pressure Process Vessels?
    Are You Experiencing Deviation Alarms In Your High Pressure Process Vessels?

    In this white paper, learn how to decrease alarms due to redundant level devices not matching, especially in applications with high pressure and/or high temperature. The importance of Gas Phase Compensation (GPC) and how it affects level readings of guided wave radar (GWR) devices is critical. The presence of polar gas also can have an effect on the accuracy of any GWR that does not have GPC when installed in applications where high temperature or pressure is present. This paper will discuss these issues and address how to overcome them.

  • Starch Mill Anaerobic & Aerobic WWTP Monitoring Program
    Starch Mill Anaerobic & Aerobic WWTP Monitoring Program

    Over the course of a 1.5-month field experiment at a Canadian starch mill biological wastewater treatment process, LuminUltra Technologies demonstrated the benefits of using 2nd Generation ATP® monitoring technology. ATP (Adenosine Triphosphate) monitoring technology is an accurate biomass measurement that can rapidly monitor all types of biological wastewater treatment processes, aerobic and anaerobic alike.

  • Bulk Emergency Chlorine Vapor Scrubber System Restored For Oklahoma City
    Bulk Emergency Chlorine Vapor Scrubber System Restored For Oklahoma City

    As a bulk emergency chlorine vapor scrubber system approached the end of its anticipated 20-year useful life, the city engaged Integrity Municipal Systems, LLC (IMS) inspected the equipment and proposed a system refurbishment plan that would ensure proper system performance and safe storage of the 30,000 gallons of corrosive caustic soda contained within it.

  • Biological Water Treatment: Only The Best Instruments Are Good Enough
    Biological Water Treatment: Only The Best Instruments Are Good Enough

    Vallviks Bruk AB, located about 200 km (125 miles) north of Stockholm, produces softwood kraft pulp and chemical pulp for export. Some years ago, increased environmental requirements led to a major investment in a biological treatment plant. Read the full case study to learn why ABB instrumentation was an obvious choice when the Swedish pulp producer Vallviks Bruk AB built a new plant for biological water treatment.

  • Ozone Vent Gas For Aeration At Wastewater Plant Expansion In China
    Ozone Vent Gas For Aeration At Wastewater Plant Expansion In China

    The Jimo, China, municipal wastewater plant was originally designed to treat a combination of municipal and textile wastewater (120,000 m3/d) with Class IB effluent limits for BOD, COD, ESS, TN, NH3-N and TP.

  • Carbon Dioxide For pH Control Of Landfill Leachate
    Carbon Dioxide For pH Control Of Landfill Leachate

    A landfill operator’s leachate treatment plant in Missouri required pH reduction following lime-softening and prior to the biological wastewater treatment process. Carbon dioxide (CO2) was chosen as a substitute for sulfuric acid due to improved process control and a reduced tendency to form scale.

  • Improving Sludge Dewatering Process Control<br>With RTC-SD
    Improving Sludge Dewatering Process Control
    With RTC-SD

    A WWTP sought solutions to improve process control, as high centrate solids caused plant inefficiencies such as high wasting rates, inefficient capacity and loading, and stress on centrifuges. Read the full case study to learn how the RTC-SD solution controlled polymer dosing in real time, allowing the WWTP to improve solids capture and increase throughput.

  • VTScada And OpWorks Provide Advanced Wastewater Reporting And Analysis
    VTScada And OpWorks Provide Advanced Wastewater Reporting And Analysis

    Rapid City is the second-largest city in South Dakota, serving over 72,000 residents. Their Water Reclamation Department treats nearly 3.5 billion gallons of wastewater annually.

  • RTC‐ST Reduces Polymer And Increases Biogas Production
    RTC‐ST Reduces Polymer And Increases Biogas Production

    Hach’s off‐the‐shelf Real-Time Control System for Sludge Thickening (RTC‐ST) adjusts the sludge thickening process in real time. Thanks to the RTC-ST, a wastewater treatment plant improved thickened sludge consistency and gas production while reducing money spent on excessive polymer dosing and maintenance.

  • The Most Misunderstood Fact Behind Dissolved Oxygen Sensors (It’s The Pressure, Not The Concentration)
    The Most Misunderstood Fact Behind Dissolved Oxygen Sensors (It’s The Pressure, Not The Concentration)

    A dissolved oxygen sensor ought to be simple to understand. Whether it is membrane or optically based, it gives a signal that is proportional to the concentration of oxygen concentration in water.

Continuous Analyzer Integrated Data Validation Continuous Analyzer Integrated Data Validation

Continuous analyzers are an integral part of the process to maintain quality, ensure compliance, and protect public health. Therefore it is imperative to ensure the analyzers are functioning properly and provide accurate and reliable data. This requires validation of the data provided by the analyzer on a routine basis. In addition some continuous analyzers incorporate internal data validation capabilities to inform the end user the reliability of the data provided by the analyzer. This paper discusses integrated data validation and how they may be integrated into SCADA systems.

Five Years Of Post-Aeration At A Wastewater Treatment Plant Five Years Of Post-Aeration At A Wastewater Treatment Plant

To protect the environment, wastewater treatment facilities across the country are required to deliver dissolved oxygen (DO) into the treated effluent, with most DO permits ranging from 2 to 10 mg/L.

Rumors, Half-Truths, And Truths About Temperature And pH Rumors, Half-Truths, And Truths About Temperature And pH

A few months ago I received a call from an angry user who was using one of our differential probes and a controller. Embedded in the probe is a thermistor that measures temperature.

More Wastewater Analysis White Papers & Case Studies

WASTEWATER ANALYSIS PRODUCTS

Aztec 600 Low Range Manganese Analyzer Aztec 600 Low Range Manganese Analyzer

The Aztec 600 Low Range Manganese Analyzer AW634 offers reliable and accurate on-line analysis of manganese up to 0.10 ppm Mn.

Capital Controls&reg; Series 17T2000 Amperometric Titrator Capital Controls® Series 17T2000 Amperometric Titrator

The Series 17T2000 Amperometric Titrator is an analytical instrument for the electrical determination of the end point of a titration for free, combined, or total chlorine residual. It can also be used to determine bromine, iodine, ozone, permanganate, and chlorine dioxide residuals.

Pro1030 pH/ORP/Conductivity Meter Pro1030 pH/ORP/Conductivity Meter

Rugged and reliable, the YSI Pro1030 provides everything you need in a handheld instrument for the measurement of either pH or ORP along with temperature, conductivity, specific conductance, salinity and total dissolved solids (TDS).

AS950 All-Weather Refrigerated Samplers AS950 All-Weather Refrigerated Samplers

Sampling has never been this easy.

Stratum PTC Purge And Trap Concentrator Stratum PTC Purge And Trap Concentrator

In 1974, Tekmar developed an idea that revolutionized the way laboratories performed Volatile Organic Compound (VOC) testing. Since then, Tekmar has continued to build on the foundation of the initial Purge and Trap technique one innovative layer at a time. The Stratum PTC builds on eight previous generations, making us the industry’s cornerstone of technique and support.

Signet 2774-2777 DryLoc® pH/ORP Electrodes Signet 2774-2777 DryLoc® pH/ORP Electrodes

The Signet 2774 - 2777 pH and ORP Electrodes feature a unique foulproof DryLoc® connector with goldplated contacts designed specifically for use with the Signet 2750 and 2760 preamplifiers, sensor electronics, and connectors.

ULTRAPEN&trade; PT1 Electrical Conductivity (EC)/TDS/Salinity Pen ULTRAPEN™ PT1 Electrical Conductivity (EC)/TDS/Salinity Pen

This instrument is designed to be extremely accurate, fast and simple to use in diverse water quality applications.

Degas Separators And Degas Relief Valves Degas Separators And Degas Relief Valves

The GDT™ Degas Separator is a patented centrifugal vortex unit that separates entrained and stripped gases from liquid (water) based on the density difference between the gas and liquid. Its unique compact design quickly and effectively separates unwanted entrained gases—such as ozone, chlorine, or methane—and requires far less space than traditional gas separators. It enables gas separation with pressure differentials of 5% or lower and at variable flows. The self-cleaning design significantly reduces maintenance and downtime, and it includes no moving parts that can wear out, break down, or require service.

More Products & Services

WASTEWATER ANALYSIS PODCASTS

Predictive Maintenance Enabled By Moving Secured Data To The Cloud Predictive Maintenance Enabled By Moving Secured Data To The Cloud

Cloud-based monitoring and reporting was all the rage at WEFTEC 2017. Water Talk sat down with Tom Perry, National Product Manager with Veolia to discuss Aquavista, one of the more established technologies for capturing critical data, storing it in the cloud and allowing it to be accessed real time, 24/7 from any smart, web-enabled device.

A New Approach To Total Nitrogen Testing A New Approach To Total Nitrogen Testing

MilliporeSigma is well known by many, but perhaps not within the water industry. That is changing, thanks to the company's work on total nitrogen (TN) testing, having recently developed a new method. Learn how and why MilliporeSigma branched out from life sciences and specialty chemicals into water, and what it means going forward.

Real-Time Monitoring Aids Adoption Of New Water Treatment Technologies Real-Time Monitoring Aids Adoption Of New Water Treatment Technologies

With the ability to store mass amounts of data, real-time monitoring and the timely analysis of that data is spurring significant change in the water industry. As Rick Bacon, CEO of Aqua Metrology Systems, explains in this Water Talk interview, high frequency data is not only aiding in the battle to identify contamination but also in summarizing performance once a solution has been installed to fix it.

Smart Sensors Have Finally Arrived Smart Sensors Have Finally Arrived

The heavy-duty, industrial strength of Aquametrix probes have made them ideal for wastewater applications. But as Mark Spencer, President of Water Analytics and the manufacturer for Aquametrix, points out in this Water Online Radio interview, they are also being accepted by a growing industrial audience.

More Analytical Instruments Podcasts

WASTEWATER ANALYSIS VIDEOS

Capital Controls&reg; MicroChem&reg;3 Multi-Parameter Analyzer And Controller Capital Controls® MicroChem®3 Multi-Parameter Analyzer And Controller

From the experts in chlorine management comes a multi-parameter water analysis system offering both chlorine measurement and control in one versatile instrument. Tailor the modular MicroChem®3 to your individual application with up to three measurement parameters. Watch the video to learn more.

Mazzei Degas Separators Selected For Wichita Aquifer Project Mazzei Degas Separators Selected For Wichita Aquifer Project

A key component of the water supply plan for the City of Wichita, Kansas, was recharging the large aquifer that lies under the region with water from the Little Arkansas River. The river basin contains substantial farming operations which, during rain events, spike the river water with the commonly used herbicide Atrazine. Atrazine concentrations in the river frequently rose forcing the city to shutdown the bank filtration system. Advanced oxidation process (AOP) was selected to remove the herbicide. The AOP reactor’s design limited the amount of hydraulic backpressure it could tolerate. Consequently, Mazzei was challenged by the project’s design team to remove the entrained gas bubbles that remained from the prior oxidation treatment at a “not to exceed” hydrostatic backpressure of 19 feet.

Utilizing Mobile Devices To Assist In Sensor Management Utilizing Mobile Devices To Assist In Sensor Management

Hach’s new Mobile Sensor Management solution is an example of the instrumentation company’s mission to provide greater clarity to its customers. As Ray Ruth, Global Product Manager at Hach, explains to Bill King in this exclusive Water Online video, the software running on your mobile device-of-choice makes sense of the Big Data coming from your sensors to assist operators and lab technicians in prioritizing maintenance, analyzing samples both in the field and the lab and can even walk you through maintenance tasks.